Product Description
Armstrong SG-2020 Suction Guide – 20" x 20" ANSI 150 Flanged
The Armstrong SG-2020 suction guide is a large-diameter ANSI 150 flanged suction guide with a 20" inlet from the system and a 20" outlet to the pump. Installed at the suction side of a centrifugal pump, it turns the flow 90°, straightens it with internal guide vanes and strains out debris before it reaches the pump – replacing an elbow, strainer and straight run of pipe in one fitting. It has a carbon steel body, guide vanes and cover plate, a stainless steel strainer and a reversible hinged cover as standard, and is rated for 175 psig and 300°F.
| Model | SG-2020 |
| Connections | ANSI 150 flanged |
| Inlet (from system) | 20.00" (500 mm) |
| Outlet (to pump) | 20.00" (500 mm) |
| Strainer free area | 1298 in² (8374 cm²) |
| Maximum pressure | 175 psig (12 bar) |
| Maximum temperature | 300°F (150°C) |
| Weight | 1310 lb (595.4 kg) |
Design & Submittals
Materials of construction
- Body: Carbon steel
- Guide vanes: Carbon steel
- Cover plate: Carbon steel
- Cover gasket: Synthetic fiber
- Strainer: Stainless steel, 0.125" (3 mm) perforations
- Start-up strainer: Fine mesh galvanized steel (remove after 24 hours)
- Cover: Reversible hinged cover, standard
Dimensions – inches (mm)
| A | B | C | D | E | F | G | H | ØI | ØJ | K | L |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 22.50 (572) | 15.50 (394) | 23.50 (597) | 41.75 (1060) | 23.50 (597) | 2.00 (50) | 34.00 (864) | 2.00 (50) | 27.50 (699) | 27.50 (699) | 29.50 (749) | 15.44 (392) |
F = drain size (NPT). G = clearance to withdraw strainer. H = support pipe size (supplied by contractor). Dimensions are for reference only; allow ±0.25" (±6 mm) tolerance. Certified dimension prints available on request.
Pressure drop
Pressure drop versus flow rate for this model is shown on the flow chart in the Armstrong submittal below.
Documents
- Model SG ANSI 150 Flanged (14"–24") Suction Guide Submittal (PDF)
- SG & FTV Product Information Brochure (PDF)
- Suction Guide Typical Specifications (DOC)
Warranty
Covered by the Armstrong Fluid Technology manufacturer's warranty.
- Armstrong Terms of Sale & Warranty – Canada (PDF)
- Conditions de vente et garantie Armstrong – Canada, français (PDF)
Installation, Maintenance, Parts Kits & Manuals
- Support the suction guide with a 2.00" (50 mm) support pipe (dimension H), supplied by the contractor.
- Leave at least 34.00" (864 mm) clearance (dimension G) to withdraw the strainer for cleaning.
- Drain connection: 2.00" (50 mm) NPT (dimension F); two 1/4" NPT ports are provided.
- The reversible hinged cover gives easy access to the strainer.
- Remove the fine mesh start-up strainer after 24 hours of operation.
- Replacement strainers, start-up strainers and gaskets are available – call (416) 236-2338 or email sales@bramhambros.com to order.