Zoeller Engineered Products X6180 Series Effluent Pump
Commercial duty effluent pumps for Class I, Division 1, Group C & D locations and Class Zone 1, Groups IIA & IIB Construction
- Cast iron construction with powder coated epoxy finish
- Seal leak probes
- Balanced concentric pump housing and impeller
- Non-clogging cast iron vortex impeller
- Oil-filled motor housing
- Finned cast iron housing for faster heat dissipation
Specifications
| Brand | Zoeller Engineered Products |
|---|---|
| Part Number | Order by model / series name |
| Model | X6180 |
| Category | Commercial / Engineered Products › Pumps › Commercial Duty |
Product Details
APPLICATIONS
- Industrial dewatering
- Automotive repair facilities sumps
- Septic tank effluent
- Low pressure effluent sewers
- Quick change oil stations
PUMP:
- Solids: 3/4” (19 mm) spherical capability
- Discharge: 1-1/2”, 2” and 3” NPT vertical
- Seals – Buna-N elastomers. Upper: carbon/stationary ceramic/rotary. Lower: carbon/stationary silicon carbide/rotary.
- Construction – cast iron ASTM A-48, Class 30, 30,000# tensile strength, protected with a corrosion-resistant, baked-on epoxy powder coating
- Seal leak probes
- Balanced concentric pump housing and impeller
- Attaching hardware – 304 stainless steel
- Square ring seals – Viton
- Impeller – Non-clogging cast iron vortex design
- Optional:
- Additional cord length available
- Silicon carbide seals
- Non-sparking rail systems
MOTOR:
- Stator – Class B & F insulation and lead wires
- 416 stainless steel motor shaft
- Oil-filled motor housing
- Finned cast iron housing for faster heat dissipation
- Integral overload protection (1 Ph)
- Thermal sensors with lead wires (3 Ph)
- Ball bearings – upper and lower high carbon chromium steel
- cCSAus rated Class I, Division 1, Groups C & D and Class Zone 1, Groups IIA & IIB Construction
- Tested to FM standards 3600 and 3615 by CSA
- Power cable length – 25’ (8 m)
Features and Benefits
- 3/4" (19 mm) spherical capability solids handling
- 1-1/2", 2" and 3" NPT vertical discharge
- Integral overload protection (1 Ph)
- Thermal sensors with lead wires (3 Ph)
- cCSAus rated Class I, Division 1, Groups C & D and Class Zone 1, Groups IIA & IIB Construction
- Tested to FM standards 3600 and 3615 by CSA
- 25' cord
Documents & Downloads
Technical Data
- Technical Data, X6180 Series, ZM3384 (389 KB)
Sales and Marketing
Owner's Manual
Dimensional Data
Guide Specs
- Guide Specs, X6161 - X6189 ZM1835 (153 KB)
Call for pricing (416) 236-2338 or email sales@bramhambros.com