Product Description
Taco Boiler Feed, Backflow Preventer & Combination Valves - 329-H
Taco Boiler Feed Valves have set the standard for dependable service. The Backflow Preventer offers added protection, preventing the system from emptying if supply pressure should fail. Coupling dependable service with added protection into one quality product is Taco’s Combination Boiler Feed & Backflow Preventer Valve.
| Brand | Taco |
|---|---|
| Series | Boiler Feed, Backflow Preventer & Combination Valves |
| Model / Part Number | 329-H |
| Category | Valves / Boiler Feed & Backflow |
Submittal Data - 329-H
| Body | Cast Iron |
|---|---|
| Inlet | 1/2” Union Press |
| Outlet | 1/2” NPT |
| A in. mm | 5-1/2 |
| Column 13 | 140 |
| B in. mm | 3-3/4 |
| Column 15 | 95 |
| C in. mm | 1-3/8 |
| Column 17 | 35 |
| Ship Wt. lbs. Kg | 1.75 |
| Column 19 | 1.1 |
Other models in the Boiler Feed, Backflow Preventer & Combination Valves series: 329-T, 335U-050-C, 335U-050-T, 335U-050-H, 335U-075-C, 335U-075-T
To Automatically Maintain System Fluid with Added Protection
Taco Boiler Feed Valves have set the standard for dependable service. The Backflow Preventer offers added protection, preventing the system from emptying if supply pressure should fail. Coupling dependable service with added protection into one quality product is Taco’s Combination Boiler Feed & Backflow Preventer Valve. The Dual Control combines the Boiler Feed with an in-line Pressure Relief Valve.
These valves automatically feed water to a system whenever pressure in the system drops below the pressure setting of the valve. The dual control combines the boiler feed valve with an in-line pressure relief valve connected at the outlet end. The backflow prevents contamination of the potable water system if supply pressure should fail.
Performance Data
Boiler Feed Valves (Reducing Valves):
Max. Fluid Temp.: 212°F (100°C)
Max. Supply Side Pressure 100 PSI (689 kPa)
Setting Range 10-25 PSI (69-172 kPa)
Factory Setting of System Side 12 PSI (83 kPa)
Dual Controls:
Max. Fluid Temp.: 212°F (100°C)
Max. Supply Side Pressure 100 PSI (689 kPa)
Relief Valve Set to Release at 30 PSI (207 kPa)
Backflow Preventer:
Max. Fluid Temp.: 250°F (121°C)
Max. Working Pressure 175 PSI (1206.6 kPa)
Features
- Fast Fill Rate on All Models
- Exclusive Fast Fill Lever Lock
- Built-In Check to Prevent Emptying the System if Incoming Pressure Fails
- Adjustable Set Pressure of 10 to 25 PSI
- Pressure Setting Adjustment Separated from Fast Fill Lever for Easy, Fast Adjustment
- Both the Backflow Preventer and the Combination Boiler Feed & Backflow Preventer Valve Carry These Certifications: ASSE Listing 1012 – 2009, SA Listing B64.3 – 11
Applications
- Hydronic Heating
Documents
- Catalog: TAC-195167 BoilerFeedValves 100-3.5 FIN
- Valves Catalog 100-3.5 FRE
- Valves Catalog 100-3.5 SPA
- Instruction Sheet: 102-553 BackflowPreventerI-SheetFIN
- REV1 BFV Instruction Sheet 102-006 HIREZ 030119
- BoilerFeedValves Submittal 101-005 fin
Call for pricing (416) 236-2338 or email sales@bramhambros.com