Product Description
Taco Accu-Flo Balancing Valves - ACUF-075-AC
With Taco Accu-Flo Balancing Valves, you will experience greater balancing accuracy than ever before. Most conventional balancing valves use a variable orifice that delivers poor balancing accuracy, high pressure drops, low regains, and an inability to read low flows.
| Brand | Taco |
|---|---|
| Series | Accu-Flo Balancing Valves |
| Model / Part Number | ACUF-075-AC |
| Category | Valves / Balancing Valves |
Submittal Data - ACUF-075-AC
| SIZE | 3⁄" 4 |
|---|---|
| CONNECTION | SWEAT |
| DIMENSIONS | 31⁄ 4 |
| Column 5 | 82 |
| Column 6 | 21⁄ 8 |
| Column 7 | 54 |
| Column 8 | 21⁄ 8 |
| Column 9 | 54 |
| Column 10 | 11⁄ 2 |
| Column 11 | 38 |
| MATERIAL | BRONZE |
| Column 13 | BRASS |
| WEIGHTS | 11⁄ 4 |
| Column 15 | 0.5 |
| C - FULL V OPEN POSITION | 3.9 |
Other models in the Accu-Flo Balancing Valves series: ACUF-050-AC, ACUF-050-AT, ACUF-075-AT, ACUF-100-AC, ACUF-100-AT, ACUF-125-AC, ACUF-125-AT, ACUF-150-AC, ACUF-150-AT, ACUF-200-AC, ACUF-200-AT, ACUF-250-F, ACUF-300-F, ACUF-400-F
With Taco Accu-Flo Balancing Valves, you will experience greater balancing accuracy than ever before. Most conventional balancing valves use a variable orifice that delivers poor balancing accuracy, high pressure drops, low regains, and an inability to read low flows. The Taco Accu-Flo Balancing Valves use a modified venturi design, instead, to deliver four to five times greater accuracy. Flow Measurement is independent of stem and ball position, and the tamper-resistant memory stop provides accurate resetting. With calibrated nameplate for presetting, all-brass interior parts, precision machining and 100% factory testing, these valves are the highest quality fixed-port venturi balancing valve on the market today.
Performance Data
Fixed-port venturi balancing valve
Bronze Body ( 1/2”-2”, Sweat and NPT)
Cast Iron Body ( 2-1/2”, 3”, 4”, Flanged)
Features
- Modified venturi design
- Blowout-proof stem
- Ball valve construction
- Calibrated nameplate for presetting
- Rated to: 1/2”-2”: 300 PSI, 250°F; 2-1/2”-4”: Class 125
- Accuracy 4-5 times greater than variable orifice balancing valves
- Flow measurement independent of stem and ball position
- Ability to read nameplate setting not required to determine flow
- Tamper resistant memory stop for accurate resetting
- Positive shut-off
- Ability to read low flows
Applications
- Hot Water Heating Systems
- Closed Cooling Circuits
- Air Conditioning Systems
- Hydronic Heating & Cooling
- Water/Glycol concentrations up to 50%
- Solar / Geothermal
Documents
- Catalog: 400-2.4
- Instruction Sheet: 402-016
- Instruction Sheet: 779inssheet
- Instruction Sheet: 402-051
- Instruction Sheet: 400-2.2A1
- Submittal: 401-019
- Submittal: 401-045
- Submittal: 401-047
- Submittal: 401-048